    More than 12 million units of packed erythrocytes are transfused annually [1, 2]. Because blood products became widely used after World War II, hundreds of millions of units have been given [1-4]. Major textbooks state that an increase of 10 g/L (1 g/dL) of hemoglobin is expected per unit of blood transfused [5-10]. Authors [5, 8, 11] have implied that after transfusion, the rate at which the hemoglobin concentration equilibrates takes about 24 hours, but the supporting evidence is scant. The ability to rapidly determine the increase in hemoglobin levels after transfusion is important in managing outpatients and acutely ill patients. A standard time to measure the hemoglobin levels would save unnecessary blood draws.

    To clarify these issues, we did a prospective study of medical inpatients at a tertiary care medical center to determine the amount of increase in hemoglobin levels after transfusion and the rapidity of equilibration. Hemoglobin levels rather than hematocrit levels were chosen because they are directly measured, not calculated [12].

    Methods

    Participants

    Patients on the general medicine service of a 700-bed teaching hospital from January to June 1993 were eligible if they were to receive a 2-unit packed erythrocyte transfusion. Exclusion criteria included age younger than 18 years, recent active bleeding, and inability to give a written informed consent. Hemoglobin concentration was measured at 15 minutes, 1 hour, 2 hours, and 24 hours after the end of the transfusion.

    Experimental Measurements

    Blood was drawn in standard 2.5 or 3 mL Vacutainer blood tubes (Bectin-Dickinson Company; Rutherford, New Jersey), and complete blood counts were measured on Coulter S plus STKR machines (Coulter Electronics; Hialeah, Florida) using standard laboratory methods. Patients were interviewed and records were reviewed for age, height, and weight data; history of congestive heart failure; use of diuretic agents; and presence of fever.

    On the basis of data from a previous study [13], it was assumed that the change in hemoglobin over 24 hours would be 18 ±8 g/L for a 2-unit transfusion. Controlling the probability of a type I error at α = 0.05, a sample of 34 patients would yield 80% power to detect a change in hemoglobin of 0.5 SDs or a 4 g/L change in hemoglobin levels.

    Statistical Methods

    The mean change in hemoglobin levels is presented together with 95% confidence intervals. The change in hemoglobin concentration over time was examined by repeated measures analysis of variance using BMPD v. 7.0 (BMDP Statistical; Los Angeles, California). Sex, age, weight, body surface area, estimated blood volume, presence of a temperature greater than 38 °C, use of diuretic agents, history of congestive heart failure, and transfusion time were each included in the analysis of variance to explore possible confounding effects on hemoglobin equilibration. Creatinine clearance [14] and blood volumes [15] were estimated using published formulas, and body surface area was calculated using standard nomograms. The association between the 24-hour change in hemoglobin levels and continuous demographic and clinical factors was examined using the Pearson correlation coefficient (P). A two-sided P value of 0.05 or less was considered significant.

    Results

    Fifty-two patients were interviewed for inclusion in the study. Six patients withdrew from the study because they received a transfusion other than a 2-unit transfusion, and two patients withdrew because they were not transfused. Five patients enrolled in the study twice. Only the first transfusion in these patients was analyzed. Thus, 39 patients were included in the data analysis.

    Study patient characteristics are summarized in Table 1. The mean hemoglobin concentration increased by 20 g/L (95% CI, 17 to 22 g/L) during 24 hours (Figure 1). Hemoglobin levels before transfusion were lower than levels after transfusion (P < 0.001), but no significant differences were noted among the 15-minute, 1-hour, 2-hour, and 24-hour hemoglobin values (P = 0.82). The change in hemoglobin concentration between 15 minutes and 24 hours ranged from 22 g/L to 20 g/L (−2.2 g/dL to 2.0 g/dL). Twenty-three (59%) of the 39 patients had hemoglobin concentrations within 6.6 g/L of their 24-hour value at 15 minutes and 35 (90%) had concentrations within 10 g/L (Figure 2). A clinically significant change in hemoglobin level is generally considered to be 6.6 to 10 g/L [12].

    Table 1. Patient Characteristics
    Figure 1. The increase in hemoglobin concentration after a 2-unit transfusion of packed erythrocytes was 20 ±2 g/L ( < 0.001). Values are expressed as mean ±SE; error bars represent the SE.
    View larger version:
    Figure 1. The increase in hemoglobin concentration after a 2-unit transfusion of packed erythrocytes was 20 ±2 g/L ( < 0.001). Values are expressed as mean ±SE; error bars represent the SE. Increase in hemoglobin concentration after transfusion.P
    Figure 2. Differences in hemoglobin concentrations between 24 hours after transfusion and 15 minutes, 1 hour, and 2 hours after a 2-unit transfusion of packed erythrocytes.
    View larger version:
    Figure 2. Differences in hemoglobin concentrations between 24 hours after transfusion and 15 minutes, 1 hour, and 2 hours after a 2-unit transfusion of packed erythrocytes. Change in hemoglobin concentration over time.

    Age, sex, weight, body surface area, estimated blood volume, history of congestive heart failure, use of diuretic agents, creatinine clearance of less than 30 mL/min, presence of fever in the near-transfusion period, and duration of transfusion were not found to influence hemoglobin equilibration (data not shown). The correlation between the 24-hour change in hemoglobin level and weight (r = −0.16), blood volume (r = −0.22), and transfusion time (r = 0.20) was not statistically significant.

    Discussion

    In 1964, Huber and colleagues [13] found the average increase in hemoglobin concentrations was 0.9 ±0.1 g/dL) in a study of 16 adult patients with mild splenomegaly. Our study confirms this finding.

    No studies exist in adults assessing the time course of hemoglobin concentration after transfusion. Studies in children have yielded conflicting results. An early study [16] involving 12 children showed that the hemoglobin concentration at 24 hours was approximately 110% of the value immediately after transfusion. A more recent study of 14 neonates [17] showed that hematocrit levels measured at 1 and 6 hours after transfusion were statistically equivalent. It has been implied that blood volume is expanded immediately after transfusion and does not return to normal for 24 hours [14]. In fact, it was shown that after large-volume saline infusions, most excess fluid is eliminated from the intravascular space in minutes [18]. Thus, erythrocyte transfusion should cause a minimal, transient expansion in blood volume.

    In 1988, O'Connell and colleagues [19] did an equilibration study with platelets that showed that the platelet counts 10 and 60 minutes after transfusion were equivalent, and this enabled the investigators to decrease clinic encounter time. Our study shows that the hemoglobin level 15 minutes after transfusion is nearly identical to the 24-hour level in patients who are not actively bleeding; it thus shows the value of rapid assessment. None of the clinical factors measured were found to influence hemoglobin equilibration. Although no relation was found for renal dysfunction or congestive heart failure, such a relation may be beyond the detection power of this study. Other limitations of this study include the fact that we examined only medical inpatients and excluded persons with active or recent bleeding (because an equilibration experiment requires a steady state).

    We conclude that transfusion with 1 unit of packed erythrocytes increases the hemoglobin level an average of 10 g/L (1.0 g/dL) and that hemoglobin measurements made 15 minutes after transfusion reflect steady state values. Such measurements should be of great value in decreasing patient waiting time after outpatient blood transfusions and decreasing the need to repeat blood tests in 24 to 48 hours.

    The opinions or assertions contained herein are the private views of the authors and are not to be construed as official or as reflecting the views of the Department of the Army or the Department of Defense.

    References

    1. 1.
    2. 2.
    3. 3.
    4. 4.
    5. 5.
    6. 6.
    7. 7.
    8. 8.
    9. 9.
    10. 10.
    11. 11.
    12. 12.
    13. 13.
    14. 14.
    15. 15.
    16. 16.
    17. 17.
    18. 18.
    19. 19.
    « Previous | Next Article »Table of Contents

    Navigate This Article